Easy Generator Installation
In an emergency, having access to reliable power is essential. It can preserve property, protect people, and allow continued service during electrical grid outages. At MPE Consulting, we offer power design and generator installation in San Diego, CA, that allow our customers to take on any challenge without losing their lights. From installation to housing, our professionals deliver total confidence.
Projects
Barona Casino
Features
- Designed new layout for a 2000kW diesel generator, ATS, service meter and service transformer.
- Designed the layout for the relocation of the existing 2000kW diesel generator with new ATS, service meter and service transformer.
- Designed connection to existing service medium voltage switch of all the site emergency generators.
Owner/Client
Barona Band of Mission Indians
General Contractor
Ickler Electric
City of Poway
Features
- Design services for addition of four pump station diesel emergency generators and automatic transfer switches.
- Design services include providing electrical line diagram, site power plans, detailed generator and fuel tank plans, duct bank and bollard details.
Owner/Client
City of Poway
General Contractor
Neal Electric
General Atomics Buildings 16 & 17
Features
- Complete Headquarter relocation.
- Integrated new tier 25,000sf server room.
- System ties into additional three buildings for building interconnection and power backup.
- New generator design incorporated a 300kW generator with the capacity for the server room and additional building backup requirements.
- The completion of these designs led to over 450,000sf of additional tenant improvements for General Atomics.
Owner/Client
General Atomics
Architect
Krenek Design Group
General Contractor
PCL
Size & Description
140,000sf 2 stories 2 buildings
Ionis Pharmaceuticals
Features
Provided electrical design and engineering services for new 175,000 sq. ft. office and pharmaceutical facility. Design services include dual 750kW emergency generators, fully redundant tier 2 data center, outdoor specialty lighting, vivarium facility, general interior lighting (title 24), coordination studies, arc flash hazard analysis, solar PV design, load analysis summaries and power engineering line diagrams and layouts for new electrical rooms/switchgear/panel boards.
Owner/Client
Ionis Pharmaceuticals / BMR Realty
General Contractor
DGA / DPR Construction
Other Clients
- ABH
- ADG
- Aethercomm
- AMCC 6290
- AMCC Oberlin
- AME
- Anacomp Vista
- Beckman Coulter
- Bioserv
- Jitterbug
- LJP
- Merriott Radiator
- MC Direct
- MediVas
- Mountain View Nursery
- Newgen
- Callaway
- Callaway HQ
- Dupont
- GIA
- Grossmont Hospital
- Hallmark Circuit
- INS
- Jenny Craig
- Pacific Center Mission Valley
- Peptisyntha
- Peregrine
- Photon 9985 Pacific Heights
- Qtron
- Sams Club Sacramento
- SDG&E
- Stemedica
- Symphony Terrace